Raychem WinterGard heat trace cable is heat tape that is professional grade. WinterGard is a 3 watt per foot heat tape that operates on 120V power. WinterGard H311, 3 watt per foot heat tape is designed for pipe freeze protection on smaller water pipes.
 
Raychem WinterGard H311 3 watt per foot heat tape is professional grade heat trace cable.
WinterGard 3 watt per foot / 120V
heat trace cable for pipe freeze protection.

Electronic heat tape temperature controller to control on and off temperature points.
ELECTRONIC TEMPERATURE CONTROL for Heat Tape Temperature Control

120V Electronic Temperature Control Electronic Temperature Control unit has a temperature differential range of 1 Degree F to 30 Degrees F. Unit can control temperatures from -30F to 220F, however you will not need the range capabilities of this control for use with heat tape for on your roof or on water pipes

Thermocube Heat Tape Thermostat for controlling power to your heat tape run.
Avoid Cold Weather Problems

Thermo Cube is a device which plugs into a standard GFI protected 120V AC outlet to automatically control turning power on and off for heat tape or stock tank heaters. By plugging the device into the Thermo Cube, when the air temperature reaches 35 degrees F, the Thermo Cube will turn on the power. When the Air temperature gets up to 45 degrees F, the power will turn off. This makes your heat tape more efficient to operate, since you are not having to run the power all the time. According to the manufacturer, you can use the Thermo Cube to control heat tape or stock tank heaters that are rated up to 1800 watts maximum or 15 amps total on 120V GFI protected circuits.

TC3 is 3-1/4" wide and 1-3/8" high and 1" thick, and has place for two 3 prong plugs to plug into it.

TC3                                  $ 23.00
Thermo Cube Heat Tape Thermostat

 

WINTERGARD H311
3 Watt Per Foot
HEAT TRACE TAPE

DEAN BENNETT SUPPLY
1-800-621-4291
Smart Phone Dialable

Raychem WinterGard H311 3 watt per foot heat tape is professional grade heat trace cable.

WinterGard heat tape is designed for use at 120V using 3 watts per foot in a length as long as 250' of heat tape. Depending on the temperature you must protect against, and the thickness of the closed cell insulation used on the pipe, the following chart applies. WinterGard is much heavier duty than Frostex Plus heat tape, and can be used for those lengths longer than 50' in length.

Raychem WinterGard heat trace cable is a professional grade 3 watt per foot, self regulating electrical cable that can be used for pipe freeze protection on small pipes. The heating cable is constructed of nickel-copper bus wires, a self regulating conductive core, and insulating jacket and a tinned-copper braid covering.

Using WinterGard self regulating heat tape has many benefits.

WinterGard H311 3 watt per foot heat tape can be overlapped and not burn out, cut to length, and saves energy. Raychem WinterGard H311 pipe freeze protection system is UL listed and CSA Certified for use in non-hazardous areas.

WinterGard Heat Tape for Metal & Plastic Pipes

WinterGard 120V 3 watt per foot heat tape is to be applied straight along the pipe. Chart indicates Metal when only able to use on Metal, and says Both when it can be used on both PVC and Metal pipe. Indicated for the size of pipe and the thickness of closed cell insulation used on the outside of the pipe to protect to the desired temperature. Normally add 1' for plug and 1' for end fitting.

Insulation Pipe Size in Inches for Metal & Plastic Pipe at 0 degrees F
Thickness 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"
1/2" Metal Metal Metal N/A N/A N/A N/A N/A N/A
1" Both Metal Metal Metal Metal Metal Metal N/A N/A
1-1/2" Both Both Both Metal Metal Metal Metal Metal Metal
 
  Pipe Size in Inches for Metal & Plastic Pipe at - 20 degrees F ( below 0 )
1/2" Metal N/A N/A N/A N/A N/A N/A N/A N/A
1" Metal Metal Metal Metal N/A N/A N/A N/A N/A
1-1/2" Both Metal Metal Metal Metal Metal N/A N/A N/A
2" Both Both Both Metal Metal Metal Metal Metal N/A
 
  Metal Pipe Size in Inches at - 40 degrees F ( below 0 )
1" Metal Metal N/A N/A N/A N/A N/A N/A N/A
1-1/2" Metal Metal Metal Metal N/A N/A N/A N/A N/A
2" Metal Metal Metal Metal Metal Metal N/A N/A N/A
 

WinterGard Heat Tape 120V 3 Watt per foot
Maximum 250' cable Use on up to 8" Pipe

$ 3.15 ft WinterGard H311 Heat Trace Cable is 3 watt per foot 120V heat tape for pipe freeze protection.
 
$ 59.25 WinterGard H908 Heat Tape Plug Kit with GFI built in. Plug kit comes with
1 gel filled end cap for end of cable.
H908 Plug Kit Installation Instructions in pdf
 
$ 13.75 WinterGard H903 Tape and Labels is the ideal way to secure your heat tape to the pipe. Super sticky tape does not become gooey and come loose when the heat from the heat tape is on.
 
$ 13.25 Gel Filled End Kits - Pack of 2 for replacement. H908 Plug kit comes with 1.


HOME          HEAT TAPE PRICE SHEET

Download our catalog in pdf format